HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
60 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-STATS (C3FRX), 1
Probable Cause
Port counter value did not match the number of frames actually transmitted. In this
case, C3FRX = number of Class 3 frames received. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate deeper problems in the motherboard
or ASIC. This message is generated by the portloopbacktest command, if
problems are found.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if
necessary.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-STATS (FRX), 1
Probable Cause
Port counter value did not match the number of frames actually transmitted. In this
case, FRX = number of frames received. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate deeper problems in the motherboard or
ASIC. This message is generated by the portloopbacktest command, if
problems are found.
DIAG-STATS (C3FRX)
DIAG-STATS (FRX)