HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
62 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-TBRAM_INC_RWTEST, 1
Probable Cause
ASIC internal registers failed read-modify-write operation. This usually indicates
an ASIC failure. This message is generated by the turboramtest command, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-TBRAM_INC_WTEST, 1
Probable Cause
ASIC internal registers failed write operation. This usually indicates an ASIC
failure. This message is generated by the turboramtest command, if problems
are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-TBRAM_INC_RWTEST
DIAG-TBRAM_INC_WTEST