HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
63Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-TIMEOUT, 1
Probable Cause
For portloopbacktest and crossporttest:
Port failed to receive frame within timeout period.
For centralmemorytest:
Port failed to detect an interrupt within the timeout period.
This can be caused by a faulty cable or deteriorated SFP. It can also indicate
deeper problems in the motherboard or ASIC.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if
necessary.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-XMIT, 1
Probable Cause
Port failed to transmit frame. This usually indicates an ASIC failure. This message
is generated by the camtest, portloopbacktest, or spinsilk
commands, if problems are found.
DIAG-TIMEOUT