HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
64 Fabric OS 3.1.3a Release Notes
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Switch: <number>, Info FABRIC-RECONFIG, 4, fabric: <reason>
Probable Cause
The fabric has reconfigured due to an offline port. The reason can be one of the
following:
Fabric Merge: Merging two fabrics.
Own ID Rcvd: A subordinate switch receives an EFP or EFP ACC that has a
payload error, listing this switch as being the principal switch.
Fabric Segment: Principal port became segmented.
Offline: Principal port went offline.
Unconfirmed domain: Switch was not able to get a domain ID. RDI ACC was
never received.
Rcv BF: Received Build Fabric (BF) command.
HA: At F2 State: According to the Fibre Channel Specification, F2 is defined
as the principal switch selection. If a failover occurs at this time, the switch is
forced to restart principal switch selection.
HA: No Upstream: After failover, the newly active fabric thinks it is
subordinate, but there is no upstream.
HA: bad EFP resp: Received an invalid EFP response.
HA: RJT EFP resp: Received an EFP reject response in which this EFP was
used for verifying the neighbor's domain list as part of fabric warm-start
recovery. A reject occurs if the neighbor is reconfiguring or the neighbor's
port is in a bad state.
FABRIC-RECONFIG