HP StorageWorks 6000-series Virtual Library System User Guide (AH809-96049, September 2010)
• Test type — Background or Read-only
• Storage pools — All or the number of the storage pool tested
• Test start time
• Test end time
• Current job count
• Total job count
• Total amount of data written during the test
• Total amount of data read during the test
• Total number of successful jobs
• Total number of failed jobs
• Status of the test
Decompression errors will be logged once per occurrence. The data fields are in order as follows.
See “Log Monitor Summary” on page 195 for descriptions not defined here:
• Decompression_error — indicates that this row of data is the decompression information.
• Decompression error ID
• Time the error occurred
• sDev Number
• LBA
• Offset
• Length
• UUID
Jobs are only logged in event of a job failure. The data fields are in order as follows:
• Job — indicates that this row of data is the job information
• Job ID
• Date of the test
• Generated job key
• Test start time
• Time of last update to the job
• Test end time
• Number of the storage pool tested
• Total amount of data written during the test at this point
• Direction — read or write
• Result — success or fail
• Message, if any, associated with the failed job
• External connect error, if any
• Source barcode of the job
• Target barcode of the job
Clearing the Hardware Compression Faults
If the VLS node is showing a hardware compression status that you think is incorrect, or if you want
to verify the status shown, you can force a rescan of the node.
From Command View VLS:
1. On the System tab, expand Chassis in the navigation tree.
Monitoring196