HP StorageWorks 6000-series Virtual Library System User Guide (AH809-96049, September 2010)

Status
Internal Health
LED Color
System board LED
and color
DIMM in slot X has reached single-bit correctable error
threshold.
DIMM in slot X is in a pre-failure condition.
DIMM in slot X is an unsupported type, but valid memory exists
in another bank.
Amber
No valid or usable memory is installed in the system.Red
DIMM failure, all
slots in one bank
(Amber)
The Health Driver has detected a cautionary temperature level.Amber
Overtemperature
(Amber)
The node has detected a hardware critical temperature level.Red
The PCI riser board assembly is not seated.Red
Riser interlock (Am-
ber)
Bank X failed over to the online spare memory bank.Amber
Online spare
memory (Amber)
The power converter module is not seated.Red
Power converter
module interlock
(Amber)
A redundant fan has failed.AmberFan module (Amber)
The minimum fan requirements are not being met in one or more
of the fan modules. One or more fans have failed or are missing.
RedFan module (Red)
The power supply signal cable is not connected to the system
board.
Red
Power supply signal
interlock (Amber)
Fan Module Locations
DescriptionItem
Power supply zone fan module (fan 1)1
Processor zone fan module (fan 2)2
Component Identification220