HP StorageWorks 6000-series Virtual Library System User Guide (AH809-96049, September 2010)

Status
9 Fault LED (am-
ber)
8 Power LED
(green)
No power to this specific power supply
-Or-
Power supply failure
OnOff
AC power present
System in standby mode
OffBlinking
Power supply on and working properlyOffOn
Power supply current limit exceededBlinkingOn
Table 13 Hard drive LED combinations
StatusFault LEDOnline LEDActivity LED
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is being accessed and is not configured as part
of an array.
OffOffOn
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is rebuilding or undergoing capacity expansion.
OffFlashingOn
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
FlashingFlashingFlashing
OK to replace the drive online if a predictive failure alert is
received, and the drive is attached to an RAID controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on controller
is not accessing the drive
.-Or-
The drive is configured as an online spare.
OffOffOff
OK to replace the drive online.
The drive has failed and has been placed off-line.
OnOffOff
OK to replace the drive online if a predictive failure alert is
received (refer to the following section for details), provided
that the array is configured for fault tolerance and all other
drives in the array are online.
The drive is online and configured as part of an array.
OffOnOff
HP StorageWorks 6000series Virtual Library System User Guide 243