Power Supply
X1400 G2 X1500 G2 X1600 G2 X1800 G2
400 Watts, Non Hot Plug
(optional redundant - see
note in options sections
on adding redundant
power )
750 Watts, Hot Plug
(optional redundant)
750 Watts, Hot Plug
Redundant
750 Watts, Hot Plug
Redundant
Power Cords
X1400 G2 X1500 G2 X1600 G2 X1800 G2
One high voltage power
cord (IEC C13 to C14)
standard
Regional or country
specifc power cord
required
Two high voltage power
cords (IEC C13 to C14)
standard
Two high voltage power
cords (IEC C13 to C14)
standard
NOTE:
X1400 G2, X1600 G2, X1800 G2 Network Storage Systems are primarily connected to PDUs in racks,
so they ship standard with only PDU C-14 to C13 power cord(s). However, you may alternatively plug an
X1000 G2 Network Storage System into a wall receptacle by ordering a separate power cord. For the
X1500, a regional or country specific power cord option must be ordered with the product. (see power cord
options section for more information).
System Fans
X1400 G2 X1500 G2 X1600 G2 X1800 G2
Non-hot plug, Non-
redundant
Non-hot plug, (optional
redundant)
Non-hot plug, redundant
Fully redundant hot plug
(N+1)
Form Factor
X1400 G2 X1500 G2 X1600 G2 X1800 G2
Rack Mount (1U), (1.75
in/4.45 cm)
Tower (5U)
Rack Mount (2U), (3.5
in/8.89 cm)
Rack Mount (2U), (3.5
in/8.89 cm)
Rack Airflow
Requirements
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency
for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling,
allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 5,350
sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow
(equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a
minimum of 7 cm (2.75 inches)
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that
can lead to thermal damage.