HP StorageWorks XP12000 Disk Array owner’s guide This guide describes features, components, options, and general operations for the HP StorageWorks XP12000 Disk Array.
Legal and notice information © Copyright 2004-2006 Hewlett-Packard Development Company, L.P., all rights reserved. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . About this guide . . . . . . . . . Intended audience . . . . . . . . Disk arrays . . . . . . . . . . . Related documentation . . . . . . Document conventions and symbols Rack stability . . . . . . . . . . HP technical support . . . . . . . Subscription service . . . . . . . HP web sites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backup batteries . . . . . . . . . . . . . . . Disk array management . . . . . . . . . . . Operating specifications . . . . . . . . . . . Temperature . . . . . . . . . . . . . . Humidity . . . . . . . . . . . . . . . . Mechanical vibration . . . . . . . . . . . AC line voltage requirements . . . . . . . 50-amp, 50 or 60 Hz, single-phase DKC 30-amp, 50 or 60 Hz, single-phase DKC 30-amp, 50 or 60 Hz, three-phase DKC .
HP StorageWorks Continuous Access Synchronous . . . . HP StorageWorks Continuous Access Asynchronous . . . . HP StorageWorks Continuous Access Journal . . . . . . HP StorageWorks RAID Manager XP . . . . . . . . . . HP StorageWorks Flex Copy XP . . . . . . . . . . . . Multipathing/high availability software . . . . . . . . . . . HP StorageWorks Secure Path . . . . . . . . . . . . . Mainframe software . . . . . . . . . . . . . . . . . . . HP StorageWorks Data Exchange XP . . . . . . . . . .
Preface About this guide This guide provides information about owning and operating the HP XP12000 Disk Array. Intended audience This guide is intended for system administrators with knowledge of: • the host hardware • the operating system • RAID technology Disk arrays Unless otherwise noted, the term disk array refers to the HP XP12000 Disk Array.
Document conventions and symbols Convention Element Blue text: Document conventions and symbols Cross-reference links and e-mail addresses Blue, underlined text: http://www.hp.
TIP: Provides helpful hints and shortcuts. Rack stability Rack stability protects personnel and equipment. WARNING! To • • • • • reduce the risk of personal injury or damage to equipment: Extend leveling jacks to the floor. Ensure that the full weight of the rack rests on the leveling jacks. Install stabilizing feet on the rack. In multiple-rack installations, fasten racks together securely. Extend only one rack component at a time. Racks can become unstable if more than one component is extended.
Subscription service HP strongly recommends that customers register online using the Subscriber’s Choice web site: http://www.hp.com/go/e-updates. Subscribing to this service provides you with e-mail updates on the latest product enhancements, newest driver versions, and firmware documentation updates as well as instant access to numerous other product resources. After subscribing, locate your products by selecting Business support and then Storage under Product Category.
Preface
1 Overview This disk array is part of the HP StorageWorks XP Disk Array family of products, which provide reliable and secure data storage and protection. These disk arrays also support multiple operating systems, platforms, and RAID groups.
Nondisruptive service and upgrades Without disrupting normal disk array operations (if alternate pathing is used), an HP support representative can: • Remove, service, repair, or replace hardware subassemblies • Use the built-in service processor (SVP) to upgrade microcode Alternate paths can be established using host failover software, alternate Fibre Channel paths, or both. CAUTION: The disk array has no user-serviceable components.
Connectivity The system can be configured to provide the following types of host connections: • Fibre Channel: Open Systems; FC-AL or Fabric; 1, 2, or 4 Gbps, single or multimode; LC-Duplex • ESCON: mainframe, serial • FICON: mainframe, LC-Duplex, single or multimode, 1, 2, or 4 Gbps • iSCSI: 8 ports per adapter, 1 Gbps • NAS: 8 ports per adapter, 1 Gbps Scalability The disk array is scalable to accommodate your current and future storage capacity needs.
Data integrity and high availability To provide the highest levels of data integrity and availability, the HP StorageWorks XP Disk Array family uses RAID technologies and redundant hardware throughout the disk arrays, including: • • • • • • • • RAID1, RAID5, RAID6 (mixing RAID levels is allowed) Mirrored write cache Dual channel adapters (CHAs) and array control processors (ACPs) Dual and concurrently active data and control paths through the array Split power domains on internal data paths Hot-pluggable b
Summary of features This section summarizes the features and specifications of the system. For the most current product information, visit the HP web site: http://h18006.www1.hp.com/ storage/enterprisestorage.html. Web-based array management The disk array comes with HP StorageWorks Remote Web Console, a browser-based interface that runs on the SVP and enables you to manage one disk array.
External storage The disk array connects to the following external storage systems and can provide access to and management of external volumes: • HP StorageWorks XP48, XP128, XP256, XP512, XP1024, XP10000, and XP12000 disk arrays • HP StorageWorks Modular Smart Array MSA1000 and MSA1500 • HP StorageWorks EVA3000, EVA4000, EVA5000, EVA6000, and EVA8000 disk arrays • Specific disk array models of other manufacturers. Consult your HP representative for details.
Required additional components • • • • • • • Cache memory Shared memory ACP pair CHIP pair Hard disk drives HP StorageWorks XP Remote Web Console HP StorageWorks LUN Configuration and Security Manager XP Optional components HP offers an extensive list of optional products and services tailored for XP disk arrays, including a full suite of software products. HP StorageWorks Command View XP or Command View XP Advanced Edition are among these options.
Hardware specifications 18 Feature Specification Power Single-phase or 3-phase DKC/DKU One XP12000 DKC, zero to four XP12000 DKUs Maximum hard disk drives 1152 Maximum spare disk drives 40 Maximum parity groups/subsystem 280 Maximum disk drive capacity 332 TB Maximum cache 256 GB Available hard disk drives 73 GB 15000 RPM FC 146 GB 10000 or 15000 RPM FC 300 GB 10000 RPM FC Maximum shared memory 12 GB (Available shared memory depends on the configuration) ACP pairs 1 to 4 (Each CHIP pa
Feature Specification Available LUNs 229,376 Maximum LUNs per port 1024 Maximum ports Fibre Channel: 224 ports ESCON: 112 ports FICON: 112 ports NAS: 32 ports iSCSI: 56 ports HP StorageWorks XP12000 Disk Array 19
Overview
2 Hardware The HP StorageWorks XP series of disk arrays are high-performance RAID-capable disk array systems used to store large quantities of data in an efficient and secure manner. There are no single points of failure in the disk arrays. They include redundant logic assemblies, controllers, disk drives, and power supplies, all of which can be removed or replaced without interrupting access to data. CAUTION: Only your HP support representative can remove or replace hardware.
Physical components The disk array includes the following major hardware components: • One disk control frame (DKC) • Zero to four disk array frames (DKUs) • One service processor (SVP) To monitor and manage the array, a Device Manager server is also required. The following figure shows the disk array with the maximum of four DKUs. The DKC alone constitutes the minimum configuration. Disk control frame The DKC controls the disk array.
Control panel Once the disk array is powered on and running normally, no user operations are required at the control panel, except when instructed by your HP support representative. The following figure shows the control panel location and layout. The accompanying table explains the control panel functions.
Item Label Indicator Description 1 SUB-SYSTEM READY LED (Green) During normal operation, this LED should be on. ON: Input/output operation on the channel interface is enabled. OFF: The system is not accepting data. 2 SUB-SYSTEM ALARM LED (Red) During normal operation, this LED should be off. ON: One or more of the following: The DC is under the voltage of the DKC part. The DC is over current. The temperature is abnormally high. An unrecoverable failure has occurred.
Item Label Indicator Description 5 REMOTE MAINTENANCE PROCESSING LED (Amber) During normal operation, this LED may be on if remote maintenance is allowed (the REMOTE MAINTENANCE ENABLE/DISABLE switch is in the ENABLE position). ON: Remote maintenance is in progress. An HP support representative is probably working on the system, but the system is online and accepting data. 6 REMOTE MAINTENANCE ENABLE/DISABLE Switch Used to permit remote service maintenance.
Item Label Indicator Description 10 PS ON/OFF Switch Used to power on/off the disk array. During normal operation, this switch should be in the ON position. The switch functions only if: The PS ENABLE switch (9) is in the ENABLE position. AND The PS REMOTE/LOCAL switch (13) is in the LOCAL position. Do not change the switch position unless directed to do so by HP service personnel. 11 EMERGENCY LED (Red) During normal operation, this LED should be on.
Item Label Indicator Description 12 AUTO PS-ON ENABLE/ DISABLE Switch Used to enable the automatic power on restart feature, which specifies how the disk array is powered on when the AC power is turned on or restored after a power outage. ENABLE: When the AC power is turned on, the disk array is powered on automatically.As with all sophisticated electronic equipment, unstable power conditions during a restart can cause problems.
Unit emergency power off switch The UNIT EMERGENCY POWER OFF switch is located on the back of the DKC cabinet. For more information about this switch, see Emergency power off.
Disk array frames DKUs are optional cabinets that allow you to expand the disk array’s storage capacity. DKUs contain physical disk drives. The disk array can include up to four DKUs. Four DKUs fully populated with disk drives provide up to 332 TB of raw storage capacity. Disk drives Each DKU can contain up to 256 hard disk drives. The disk array automatically detects and corrects disk errors, and an HP support representative can replace any of the disk drives without disrupting user activity.
Backup batteries In each frame (DKC and DKU), internal nickel-metal-hydride batteries provide backup power for the cache memory, shared memory, ACPs, CHIPs, and disk drives. If AC input power is lost, the backup batteries enable the disk array to continue normal operations for up to one minute. If power is not restored within one minute, the disk array executes either the De-Stage or Backup battery operation mode.
Disk array management HP Remote Web Console (RWC) allows browser-based management of a single disk array. The optional HP Command View XP Advanced Edition software may be installed on an optional Device Manager server to enable additional management capabilities, including the ability to manage multiple arrays. Other HP StorageWorks XP Disk Array software may also be installed on this host; see HP StorageWorks XP Disk Array family of software products for information about optional HP software products.
Operating specifications This section provides some general specifications. For complete specifications, see the system site preparation guide, available on the HP XP Disk Array web site: http://h18006.www1.hp.com/storage/xparrays.html.
Humidity Protect the disk array from excessive humidity. You should not observe condensation in or around the product under any conditions. There is no procedure for recovery from moisture condensation.
AC line voltage requirements This section lists the AC power recommendations for each power cord. Each DKC or DKU has two or four power cords. In case of a failure of the power source for one cord, the power requirements, and therefore the current requirement for the remaining power cord, will double. For details on electrical specifications, cabling, and connectors, see the HP StorageWorks XP12000 Disk Array site preparation guide.
30-amp, 50 or 60 Hz, three-phase DKC Parameter 200 VAC 208 VAC 60 Hz only 220 VAC 230 VAC 240 VAC 380 VAC 400 VAC 415 VAC Rated line current per power cord (amps RMS) 13 12.5 11.9 11.3 10.9 6.9 6.5 6.
30-amp, 50 or 60 Hz, single-phase DKU Parameter 200 VAC 208 VAC 60 Hz only 220 VAC 230 VAC 240 VAC Rated line current per power cord (amps RMS) 9 8.7 8.2 7.8 7.5 Number of power cords 4 4 4 4 4 30A 30A 30A 30A 30A 4 4 4 4 4 Recommended circuit breakers Number of circuit breakers. Units with only two power cords require only two circuit breakers.
3 Operations During normal operations, the disk array does not require your intervention and you should not attempt to open the disk array cabinets. The disk array reports any service information messages (SIMs) to the SVP and the Device Manager server. If the array is set up to “phone home,” the SVP automatically reports SIMs to the HP Storage Technology Center (STC). For more information about SIMs, see Service information messages.
General safety guidelines Carefully read these safety guidelines and follow them when working with the disk array. • Fully understand and follow all hazard warnings in this guide and on warning labels on the disk array. These hazard warnings help you to prevent or reduce the risk of death, personal injury, or product damage. Hazard warnings include alert headings consisting of an alert symbol and the word Caution or Warning.
CAUTION: If you detect any abnormal noise, smell, or smoke coming from the disk array, immediately power off the disk array by following the emergency power off procedure later in this chapter. For routine power off in non-emergency situations, contact your HP support representative. CAUTION: Do not power off the system unless it is an emergency situation and you follow the procedure for Emergency power off. CAUTION: Keep the front and rear doors closed at all times.
Powering down the disk array Two situations may arise when you need to power down the system: • Planned power off • Emergency power off Planned power off Occasionally, you may need to plan a site power outage, such as during alterations to the data center, inspections, or work by the electric company. If a scheduled power outage will affect the disk array, contact your HP support representative to schedule a planned power off.
To power off the disk array in an emergency: 1. Locate the UNIT EMERGENCY POWER OFF switch on the back side of the DKC. Its location is shown in the following figure. 2. Pull the switch up and then out towards you. The disk array shuts down immediately. The UNIT EMERGENCY POWER OFF switch mechanically locks itself in the off position to prevent anyone from restoring power in a potentially hazardous situation. WARNING! The UNIT EMERGENCY POWER OFF switch provides only partial power off capability.
Recovering from an unplanned power outage Unplanned power outages occur when the primary building power is lost due to electrical blackouts, thunderstorm activity, or similar occurrences, and input AC power is not received by the disk array. The disk array will maintain its state and recover when power is restored. The disk array cache is powered by backup batteries that will maintain the array state for up to 48 hours, depending on the selected battery operation mode.
Automatic restart when power is restored CAUTION: As with all sophisticated electronic equipment, unstable power conditions during a restart can cause problems. HP recommends automatic power on restart only if the power to the disk array is subject to power conditioning equipment, such as a UPS, to ensure that the power restored to the disk array is stable.
Operations
4 Software This chapter describes HP’s suite of software products available for your system. HP StorageWorks software: • • • • • Augments critical array capabilities Helps optimize your IT resources Improves overall storage availability Simplifies disaster recovery Improves data security Before installing a software package, refer to the software product documentation to verify equipment requirements.
Storage area management software HP OpenView Storage Area Manager suite HP OpenView Storage Area Manager provides comprehensive, centralized management across distributed, heterogeneous storage networks.
HP Storage Essentials The HP Storage Essentials suite delivers integrated heterogeneous functionality for network (DAS, SAN, NAS) management, storage resource management, provisioning and application infrastructure monitoring.
Device and configuration management software HP StorageWorks XP Remote Web Console and Command View XP Advanced Edition (AE) HP Remote Web Console (RWC) which comes installed on the SVP, is the standard software package for managing the XP disk array. RWC allows you to install and manage the disk array but does not allow you to manage multiple arrays. To manage multiple HP XP disk arrays, you will need the optional HP Command View XP Advanced Edition software.
HP StorageWorks Cache LUN XP HP Cache LUN XP lets you reserve areas of memory cache on the HP XP disk arrays to store frequently accessed information. It improves file access times and enables faster data transfers. Assigning information to on-board cache speeds up access to your data because cache-resident data is available at host data transfer speeds for both read and write operations. HP Cache LUN XP redirects I/O requests from the XP disk drives to data locked in the array’s cache.
• Rejection of file system device inquiry requests • Reporting of access failures to host server • Allows XP disk array deployment in data retention solutions that assist in meeting SEC-related data integrity requirements (Once the retention period is set, it cannot be changed. Purchase and deployment of this product does not by itself ensure that regulatory/legal requirements for data retention will be met, and compliance is not implicitly or explicitly guaranteed.
HP StorageWorks XP Tiered Storage Manager HP StorageWorks XP Tiered Storage Manager is a plug-in for the HP StorageWorks Command View XP Advanced Edition Software. The plug-in migrates data to tiered storage systems according to quality of service requirements, matching the defined quality requirements of the data to the appropriate storage tier. It is a completely non-disruptive application that you can schedule or start immediately, once you have designed a migration plan.
Performance management software HP StorageWorks Auto LUN XP HP Auto LUN XP provides monitoring and disk usage analysis for your disk array based on user thresholds. HP Auto LUN develops a plan to migrate impacted data volumes to lower usage LUNs, using the data acquired during monitoring. You can perform the migration manually or automatically.
Replication software HP StorageWorks Business Copy XP and Snapshot XP HP Business Copy allows you to make up to nine ongoing copies of data for nonproduction activities such as backup, batching, and system testing. HP Business Copy and the disk array now support enhanced HP Snapshot features. HP Snapshot is optional software that creates multiple, point-in-time, online, local copies without impacting primary production operation.
HP StorageWorks Flex Copy XP HP Flex Copy XP enables bidirectional, server-independent data transfer between the HP XP12000 and these HP Disk Array storage systems: XP48/128/256/512/1024, MSA1000, MSA1500, EVA 3000, EVA 4000, EVA 5000 EVA 6000, EVA 8000. Data can be transferred locally within a single data center or over metropolitan distances in a distributed storage network, without consuming server or LAN performance resources.
Mainframe software HP offers a wide range of mainframe software, including disaster recovery applications, point-in-time copy solutions, backup applications, and migration solutions.
Business continuity solutions HP OpenView Data Protector Backup and restore with HP OpenView Data Protector. • Offers new levels of recovery with a service-driven management approach • Enterprise-wide data protection • Eliminate recovery windows with instant recovery, system disaster recovery, and direct backup HP StorageWorks Cluster Extension XP HP Cluster Extension XP offers protection against system downtime from a variety of faults, failures, and disasters.
HP StorageWorks Fast Recovery Solution for Windows 2003 HP Fast Recovery Solution (FRS) for Windows 2003 enables quick recovery of Microsoft Exchange and SQL databases. Using the HP Business Copy secondary volumes, FRS can recover these databases in minutes rather than hours.
Software
5 Troubleshooting Service information messages The system generates service information messages (SIMs) to identify normal operations, service requirements, and failures. SIMs are generated by the SVP and the system microprocessors. Your HP support representative uses the SIMs to monitor and troubleshoot the system. You can view SIMs using the system’s management software.
Failure detection and reporting process If a failure occurs in the system, the failure is detected and reported to the system log, the SIM log, and the HP STC, as shown in the following figure and table. Item 60 Description 1 A failure is detected in the system. 2 The failure is reported to the system. 3 The system stores the failure information in the system log.
6 Regulatory statements FCC EMC statement (USA) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Spécification ATI Classe A (France) DECLARATION D’INSTALLATION ET DE MISE EN EXPLOITATION d’un matériel de traitement de l’information (ATI), classé A en fonction des niveaux de perturbations radioélectriques émis, définis dans la norme européenne EN 55022 concernant la Compatibilité Electromagnétique.
Harmonics conformance (Japan) German noise declaration XP12000: Schalldruckpegel Lp = 70 dB(A) Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1988 / EN 27779:1991 (Typprüfung) HP StorageWorks XP12000 Disk Array 63
Laser safety When equipped with native Fibre Channel adapters, this product contains a laser internal to the Optical Link Module (OLM) contained on the 8-port Fibre Channel Adapter board and 8-port FICON board, and on the 16-port Fibre Channel Adapter board and 16-port FICON board for connection to a fibre communications network.
Japan DENAN law cordset caution Please use the supplied power cord. The power cord may not be used with other products.
European WEEE statements Czech Danish Dutch 66 Regulatory statements
English Estonian Finnish HP StorageWorks XP12000 Disk Array 67
French German Greek 68 Regulatory statements
Hungarian Italian Latvian HP StorageWorks XP12000 Disk Array 69
Lithuanian Polish 70 Regulatory statements
Portuguese Slovak Slovenian HP StorageWorks XP12000 Disk Array 71
Spanish Swedish 72 Regulatory statements
Glossary ACP Array control processor. On some XP models, such as the XP12000, the ACP handles the passing of data between the cache and the physical drives. On other XP models, such as the XP10000, this function is handled by the disk adapter on the MIX board. AL Arbitrated loop. AL-PA Arbitrated loop physical address. allocation The ratio of allocated storage capacity versus total capacity as a percentage. “Allocated storage” refers to those LDEVs that have paths assigned to them.
The benefit of cache memory is that it speeds I/O throughput to the application. The larger the cache size, the greater the amount of data buffering that can occur and the greater throughput to the applications. XP arrays support a range of cache memory. In the event of power loss, battery power holds up the contents of cache for up to 36 hours. 74 CE Customer engineer. channel adapter (CHA) The channel adapter (CHA) provides the interface between the disk array and the external host system.
disk recovery and restore unit (DRR) The unit responsible for data recovery and restoration in the event of a cache failure. disk group The physical disk locations associated with a parity group. disk type The manufacturing label burned into the physical disk controller firmware. In most cases, the disk type is identical to the disk model number.
GB Gigabytes. GLM Gigabyte link module. HA High availability. HBA Host bus adapter. A built-in function or a card installed in a PC or other host computer to enable connection of the host to the SAN. host mode Each port can be configured for a particular host type. These modes are represented as two-digit hexadecimal numbers. For example, host mode 08 represents an HP-UX host. hot standby Using two or more servers as a standby in case of a primary server failure.
MIX A circuit board in the disk control unit that includes disk adapters and channel adapters for interfacing disk drives and the host to cache memory. mirroring consistency The consistency (usability) of data in a volume (for example, S-VOL). mm Millimeters. MR Magnetoresistive. ms, msec Milliseconds. mutual hot standby system Two servers that are poised to cover for each other if necessary. NAS Network attached storage.
P-P Point-to-point. PS Power supply. Russellstoll®, a brand of electrical plugs and receptacles manufactured by Thomas & RS 78 Betts Corporation. RAID Redundant array of independent disks. RAID group See “array group.” RAID level A RAID Level is one of the ways that disk drives are grouped together to improve performance, data availability/reliability or both. RAID levels are defined from RAID0 to RAID6. HP StorageWorks Disk Arrays in the XP product family support RAID1, RAID5 and RAID6.
TB Terabyte. TCP/IP Transmission control protocol/Internet protocol TID Target ID. VSC Volume size customization. Synonymous with CVS. VOLID Volume ID. volume Synonymous with LDEV.
Glossary
Index Symbols features software, 14 conventions text symbols, 7 conventions, document, A D AC line voltage, 34 AC power cords, 34 array management, 15 audience, 6 Auto LUN XP, 52 automatic restart, 27, 43 B backup battery operation mode, 30 batteries, backup, 30, 42 business continuity solutions, 56 Business Copy, 53 C cache battery backup, 30 Cache LUN XP, 49 Command View XP, 15, 31, 48 Command View XP Advanced Edition, 48 components hardware, 22 included, 16 optional, 17 required additional, 17 c
external storage, 16 F failure detection and reporting process, 60 features data integrity, 14 high availability, 14 Flex Copy XP, 54 H hardware control panel, 23 disk array frame, 29 disk control frame, 22 disk drives, 28, 29 features, 16 normal operations, 37 physical components, 22 RAID options, 29 service processor.
replication software, 53 restart automatic, 43 manual, 42 S safety guidelines, 38 scalability, 13 Secure Path, 54 service, 12 service information messages, 59 service processor.