6.3.2 HP StoreAll OS Release Notes

3. Wait for a few seconds to let the Store archive propagate through the cluster and then restart
the active FM.
The credentials management service (hpsp_credmgmt) will not allow adding a credential for a
new MSA storage array after the credential database is created. The workaround is to install the
credentials manually.
To install the credentials manually:
1. Enter the hpsp_couplet_info -i command to get a list of UUID for attached MSA
enclosures. Each enclosure is on a separate line, as shown in the following example of the
command and its output:
[root@ib25-02s1 security]# hpsp_couplet_info -i
500c0ff1390c0000
2. Install the credentials for a single MSA by running the following four commands once for
each MSA that the hpsp_couplet_info command lists in step 1. Replace
<MSA_SAS_BASE_ADDRESS> with one of the UUIDs as provided by the output of the
hpsp_couplet_info command.
hpsp_credmgmt --update-cred -s
couplet:couplet/array/<MSA_SAS_BASE_ADDRESS>/mgmtport_a/rw
--cred-type upwpair --cred-username manage --cred-password '!manage'
hpsp_credmgmt --update-cred -s
couplet:couplet/array/<MSA_SAS_BASE_ADDRESS>/mgmtport_a/ro
--cred-type upwpair --cred-username monitor --cred-password
'!monitor'
hpsp_credmgmt --update-cred -s
couplet:couplet/array/<MSA_SAS_BASE_ADDRESS>/mgmtport_b/rw
--cred-type upwpair --cred-username manage --cred-password '!manage'
hpsp_credmgmt --update-cred -s
couplet:couplet/array/<MSA_SAS_BASE_ADDRESS>/mgmtport_b/ro
--cred-type upwpair --cred-username monitor --cred-password
'!monitor'
3. To verify your installation of the credentials, list the credentials by entering the following
command:
hpsp_credmgmt --get-cred -s couplet:couplet/* --output-sl
The command displays the credentials for your system. Your output would differ from the
following example to reflect your system configuration:
10.125.2.221|monitor|!monitor|couplet:couplet/array/500c0ff1390c0000/mgmtport_b/ro
10.125.2.221|manage|!manage|couplet:couplet/array/500c0ff1390c0000/mgmtport_b/rw
10.125.2.220|monitor|!monitor|couplet:couplet/array/500c0ff1390c0000/mgmtport_a/ro
10.125.2.220|manage|!manage|couplet:couplet/array/500c0ff1390c0000/mgmtport_a/rw
SMB
If you plan to use Microsoft Robocopy to migrate files to a StoreAll HP-SMB share that has data
retention enabled, you must:
Disable the HP-SMB AllowPVFSFilemodeChange registry setting on every StoreAll cluster
nodes and restart HP-SMB. Disabling this registry setting prevents a file from transitioning to
a WORM or retained state through HP-SMB. However, it does not inhibit autocommit or the
ability to transition files to a WORM or retained state using other protocols.
Disable autocommit if it is enabled.
18 Workarounds