Customer self repair (CSR)
The following information is included in all CSR documents:
• Before you begin—Component-specific precautions or notices. Be
sure to read and observe these statements.
• Verifying component failure—Before replacing a component, confer
with HP technical support to verify that the hardware component has
failed and that you are authorized to replace it. Verification proced-
ures may include:
• Viewing LED illumination patterns on the enclosure and the com-
ponent.
• Viewing system event logs or other reports generated by systems
management tools.
• Removing the failed component—Procedural steps to properly remove
the component, including illustrations.
• Installing the replacement component—Procedural steps to properly
install the component, including illustrations.
• Verifying component status — After replacing the component, verify
that the replacement component is operating properly. Verification
procedures may include:
• Viewing LED illumination patterns on the enclosure and the com-
ponent.
• Viewing system event logs or other reports generated by systems
management tools.
Before you begin
CAUTION:
When handling system components, there is a danger to
equipment from electrostatic discharge (ESD). Use proper
anti-static protection at all times:
• Keep the replacement component in the ESD bag until needed.
• Wear an ESD wrist strap grounded to an unpainted surface
of the chassis.
• If an ESD wrist strap is unavailable, touch an unpainted surface
of the chassis before handling the component.
• Never touch connector pins.
CAUTION:
Be sure the replacement is available before removing the failed
component. Removing a component impacts airflow and cooling
within the enclosure.
nl
nl
nl
nl
Verifying component failure
Check for an error message on the seven-segment display.