6.0 HP StorageWorks X9000 File Serving Software CLI Reference (TA768-96040, October 2011)

Run phase 2:
ibrix_fsck -p 2 -f FSNAME [-s LVNAME] [-c] [-o "options"]
The command can be run on the specified file system or optionally only on segment LVNAME. Use
-o to specify any options.
Run phase 3:
ibrix_fsck -p 3 -f FSNAME [-c]
Clear the INFSCK flag:
ibrix_fsck -f FSNAME [-C]
Options
DescriptionOption
Specifies a block size in KB.-B BLOCKSIZE
Clears the INFSCK flag.-C
Specifies the number of an alternate superblock, generally used only if the normal superblock
is corrupted.
-b ALTSUPERBLOCK
Runs ibrix_fsck in corrective mode (the default is analytical mode).-c
A file system.-f FSNAME
Options for the command.-o "options"
Runs the specified phase (0, 1, 2, or 3).-p 0|1|2|3
Specifies a logical volume (segment) name.-s LVNAME
Shows the usage for this command.-?
See also
ibrix_host, ibrix_umount
58 X9000 File Serving Software commands