3.03.0a HP StoreEasy 1000 Storage Release Notes (B7D88-96316, June 2013)

Pool Manager
If you use the Array Configuration Utility (ACU) to create one or more pools and then use Pool
Manager to grow a pool, Pool Manager may report that the operation failed even though it
actually succeeded. This can occur if parity initialization is still in progress on the newly created
pool. HP recommends that you use Pool Manager for all operations on storage pools.
If this occurs, refresh Pool Manager and verify the drive count on the pool. It is likely that the grow
operation will have succeeded despite the error report. Alternatively, you can retry the grow
operation after parity initialization on the new pool is complete.
On the StoreEasy 1000, if a LUN with a RAID level of 1, 0, or 1+0 is extended, the corresponding
LUN transformation job is not displayed in the View Jobs tab of Pool Manager.
Open the ACU and view job status for the affected LUN.
System installation and recovery
Command-line Tools and Internet Printing Client features are not installed by default with the
operating system.
Use Windows Server Manager to manually install these features:
1. Select Features and then click Add Features.
2. Select Command-line Tools (located under Windows Server Backup features) and Internet
Printing Client in the features list.
3. Click Next and complete the Add Features Wizard installation process.
The time zone selected during the image process is not retained. The image process allows you
to set the time zone; however, the time zone is always set to Pacific time when the operating
system comes up for the first time.
Change the time zone after the system is fully imaged.
When performing the system recovery process on an HP StoreEasy 1430 or 1530 system using
an internal DVD drive, the process may fail.
Use an external DVD drive, iLO, or a USB flash device.
Windows Server Manager
In Windows Server Manager, the Repair Virtual Disk option is unavailable.
When a virtual disk fails, you cannot use the Repair Virtual Disk option in Windows Server
Manager to fix it because the option is unavailable. Nor can you use the Repair-VirtualDisk
cmdlet in Windows PowerShell. Instead, you may be able to use the Array Configuration Utility
to repair a failed virtual disk, depending on the type of failure.
Installation instructions
Instructions for installing new systems are provided in the HP StoreEasy 1000 Storage Quick Start
Guide.
Effective date
June 2013
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the
documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hp.com). Include the document title and part number, version number, or the URL when
submitting your feedback.