HP X5000 G2 Network Storage System Administrator Guide

Replacing the 1210m controller card
1. Install the cache module and capacitor in the cache module slot of the replacement controller.
2. Close the ejector latches on the cache module slot.
3. Install the replacement controller card (1, Figure 129 (page 113)). Press down on the connector
to seat the card (2).
CAUTION: Be sure not to press on the cache module when replacing the controller card. It
could damage the cache module and result in errors.
Figure 129 Replacing the 1210m controller card
4. Tighten the captive screws.
5. Replace the capacitor in its cradle.
6. Install the access panel.
7. Install the server blade in the enclosure.
8. Confirm that the replacement 1210m controller is running current firmware (see“Upgrading
a component's firmware” (page 56)).
NOTE: You must reboot the storage solution after updating firmware on the 1210m controller
because both controllers must be updated at the same time.
Removing and replacing the 1210m cache module
Removing the 1210m cache module
WARNING! Wear gloves or use care when removing the capacitor pack to avoid physical injury.
CAUTION:
When replacing the cache module, ensure that the replacement is compatible with the 1210m
controller. Otherwise, the controller could malfunction and you could lose data.
ESD can damage electronic components. Be sure you are properly grounded before performing
this procedure.
1. Back up all data.
2. Close all applications.
3. Power off the server blade.
Removing and replacing the 1210m controller board components 113