HP X5000 G2 Network Storage System Administrator Guide

SHOW ENCLOSURE STATUS
Syntax
SHOW ENCLOSURE STATUS
Description
Displays the basic health and status of the enclosure and its subsystems. If the enclosure shows
degraded, the subsystems causing the state change are detailed (for example, failed or missing
redundant module).
Restrictions
None
SHOW ENCLOSURE TEMP
Syntax
SHOW ENCLOSURE TEMP
Description
Displays current status and reading of some of the thermal sensors in the enclosure. If the sensor
is unreadable due to absence of power or failure, ? is displayed.
Restrictions
Only integral measurements in Celsius are displayed (fraction, if any, is truncated).
Not every sensor that is present in the enclosure is reported.
For blades a virtual ambient (not a physical) sensor temperature is displayed that is computed
by iLO based on its thermal model and measurements from several sensors. This model is
transparent to the EM. Until this calculation normalizes, 0 is shown as the temperature for the
blade, so that right after power on of the enclosure, it takes several seconds before a nonzero
value is shown for the blades while other sensors are reported immediately.
SHOW FRU
Syntax
SHOW FRU
Description
Displays summary information on field replaceable units (FRUs) within the enclosure. Information
provided in this section can quickly aid the administrator in contacting HP Customer Service for
troubleshooting, repair, and ordering replacements.
Restrictions
Only displays known/live data.
Some FRU devices are not accessible by the EM when the enclosure power is off so their
information is unavailable.
SHOW IOMODULES
Syntax
SHOW IOMODULES
142 Managing the EMU