HP X5000 G2 Network Storage System Administrator Guide

Restrictions
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning “enclosure power is off” if this command is issued when power is off.
SHOW SERVER STATUS
Syntax
SHOW SERVER STATUS { ALL | <bay#>[ { , | - } <bay#>] }
Description
Displays current status of the server blade in the specified bay or both bays.
Restrictions
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning “enclosure power is off” if this command is issued when power is off.
Enclosure control
The commands in the section provide various enclosure control functions.
DOWNLOAD CONFIG
Syntax
DOWNLOAD CONFIG <URL>
Description
Downloads a previously saved configuration script file from a specific IP host then executes it. This
command should be used to recover configuration after replacement of a failed EMU.
Supported protocols are HTTP, FTP, and TFTP. The URL should be formatted asprotocol://host/
path/file. If your FTP server does not support anonymous connections, you can specify a
username and password by replacing the host part in the above format with
username:password@host.
Restrictions
Only IPv4 is supported in EM 1.0 or later.
RESTART EM
Syntax
RESTART EM
Description
This reboots the Linux OS and restarts the EM software. It is necessary to do this command following
a firmware downgrade using UPGRADE IMAGE FORCE. Except when in script mode, the user is
prompted for an explicit confirmation, which must be given or the command is terminated.
Restrictions
None
Enclosure control 149