HP X5000 G2 Network Storage System Administrator Guide

Description
Sets the blue enclosure UID. The enclosure has a UID on both the front and rear of the enclosure.
However, the front UID is only lit when enclosure power is on, while the rear UID is only lit when
standby power is on. The Unit Identification LED displays as steady on, off, or one of two blinking
speeds. The system confirms the operation. There is no particular meaning to SLOW or FAST.
Restrictions
Blinking rates are not user definable. SLOW is 1 Hz; FAST is 2 Hz.
SET FACTORY
Syntax
SET FACTORY
Description
Restores configuration settings back to the factory defaults, including deleting any created user
accounts, except for the Administrator password, which remains unmodified. The EM restarts after
restoring the configuration settings. If the enclosure power is on, the iLOs are reset (to force a
refresh of the enclosure information passed to iLO).
Restrictions
None
SET RACK NAME
Syntax
SET RACK NAME "<rack name>"
Description
Sets the user-defined string reported with SHOW RACK NAME command. The system responds with
confirmation of the change. The default (unset by user) rack name is ‘UnnamedRack.
Restrictions
<rack name> must be 1 to 32 characters long and includes all alphanumeric, underscore (_),
and hyphen (-) characters.
UPDATE IMAGE
Syntax
UPDATE IMAGE { [ FORCE ] <URL> }
Description
Downloads a new EM firmware image from the network and uses it to update the Enclosure
Manager’s firmware. Supported protocols are HTTP, FTP, and TFTP. The EM validates the image
before performing the update. Unless the session is in script mode, the EM requests confirmation
before performing the update.
After update, the EM is restarted unless the FORCE operation was used in which case a manual
invocation of RESTART EM is necessary to reboot the new firmware.
152 Managing the EMU