HP X5000 G2 Network Storage System Administrator Guide

4. Remove the top back panel by pressing the panel release button and lifting the latch to slide
the top back panel off.
5. Open the release handle (1, Figure 48 (page 69)), and pull up to remove the server interposer
board (2, Figure 48 (page 69)).
NOTE: You may need to use significant force to accomplish this task.
Figure 48 Removing the server interposer board
Replacing the server interposer board
1. With the release handle open, align the server interposer board with the alignment pins (1,
Figure 49 (page 69)), and then close the server interposer release mechanism (2, Figure 49
(page 69)).
NOTE: Remember to move the server backplane power cable out of the way of the alignment
pins.
Figure 49 Replacing the server interposer board
2. Reinstall the top back panel.
3. Replace the enclosure in the rack as described in “Inserting the system enclosure into the rack”
(page 68).
Removing and replacing the server interposer board 69