HP X5000 G2 Network Storage System Release Notes 2.03.
© Copyright 2012 Hewlett-Packard Development Company, L.P. Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.
Version: 2.03.1a Description These release notes describe HP X5000 G2 software version 2.03.1a and can be used to upgrade your existing HP X5000 G2 that is running QR version 2.01.0a or later. See “Determining the current version” (page 11) for more information. Update recommendation Critical Supersedes 2.03.0a Product models HP X5520 G2 Network Storage System Components The following list contains all component updates since the release of 2.01.0a. • HP OOBE and Server Manager 2.3.
NOTE: There is no update to Adobe Acrobat Reader in 2.03.1a (it is not included in the service release). The version you are running depends on the previous version of X5000 G2 software that you installed: 10.1.2 (if previous version is 2.03.0a), 10.1.1 (if previous version is 2.02.0a), or 10.0.0 (if previous version is 2.01.0a). • Oracle JRE 6 Update 27 6.0.270 • Oracle JRE 6 Update 27 (64-bit) 6.0.270 • Storage Manager for SANs (removed) • New HP certificates Firmware 2.03.
NOTE: Localized versions of the HP X5000 G2 Network Storage System Online Help 1.2.1 are installed when you install the service release. The localized versions of the online help are not included in the current version of the System Recovery DVD. If you require localized online help, install the service release. Enhancements 2.03.1a Not applicable 2.03.0a • Added a Documentation section to the Getting Started topic (Server Manager and Online Help). • Revised the Create File Server wizard.
KB2618444 (http://support.microsoft.com/kb/2618444) KB2618451 (http://support.microsoft.com/kb/2618451) KB2620704 (http://support.microsoft.com/kb/2620704) KB2620712 (http://support.microsoft.com/kb/2620712) KB2621440 (http://support.microsoft.com/kb/2621440) KB2631813 (http://support.microsoft.com/kb/2631813) KB2633870 (http://support.microsoft.com/kb/2633870) KB2633873 (http://support.microsoft.com/kb/2633873) KB2639417 (http://support.microsoft.com/kb/2639417) KB2641653 (http://support.microsoft.
KB2660075 (http://support.microsoft.com/kb/2660075) KB2679255 (http://support.microsoft.com/kb/2679255) Fixes 2.03.1a • The previous version of the I/O module firmware was causing false fan alerts to be generated intermittently. The alerts would indicate that there was a change in the status of the fan. The fix (updated I/O module firmware) eliminates these false alerts.
• When the I/O modules of the external disk enclosure is flashed by the Firmware Management Tool, the Port field now correctly displays the port ID for each I/O module. Previously, the same value displayed in the Port field for both I/O modules. • The Enclosure Manager firmware update would fail if the HP 1210m controller could not detect the Enclosure Manager IP address. 2.02.0a • The enclosure name is now updated in the System Manager after changes are made on the Enclosure Settings dialog box.
automatically set as the default gateway. As a result, you cannot manage the Enclosure Manager settings remotely through ssh because the gateway is incorrect. Workaround: Use Remote Desktop Connection to access the nodes and the Enclosure Manager settings. Use the Enclosure Manager Settings tool to fix the assignment of the gateway, which will enable you to use SSH.
Viewing the System Management Homepage in Japanese is missing some information that is displayed when viewed in English When viewing the System Management Homepage in Japanese, some of the enclosure and 1210m controller information that is displayed when viewed in English is not displayed when viewed in Japanese. Workaround: To view the missing information, run a report using the Reports tab in the System Manager.
Report not generated when HP Storage Viewer is running If HP Storage Viewer is running when you attempt to generate a report in the System Manager Reports tab, the Reports tab eventually indicates that a report was not generated. Workaround: To resolve this issue, ensure that HP Storage Viewer is not running when generating a report. Utility is shown as not installed After installing the service release in Japanese, the HP Lights-Out Online Configuration Utility is incorrectly shown as not installed.
Installation instructions (new storage systems) Instructions for installing the storage system are provided in the HP X5000 G2 Network Storage System Quick Start Guide. Installation instructions (existing storage systems) Before installing the service release, ensure that the system drive where the software will be installed has a minimum of 1 GB of available space to accommodate the upgrade. The specific amount of disk space required depends on the components selected for installation.
NOTE: • If you launch more than one instance of the executable, an incorrect error message is displayed. Instead of indicating that another instance is running, the following error message is displayed: 7 zip, internal error, code 105 • 4. 5. When you are prompted to reboot during the installation, the "Installation is complete" message displays in the installer window with two checkboxes—Cleanup and Reboot (both selected by default).