HP StoreEver Enterprise Systems Library (ESL) G3 Tape Library HDEM Magazine Calibration Target Replacement Instructions

6. Repeat the above steps for any additional
magazines that need to be removed.
Install the new calibration target with
magazine
1. Insert the replacement magazine with calibration
target in the appropriate space, making sure the
hooking tabs align with the anchor slots and the
barcode label is at the top.
CAUTION: Calibration targets for the
HDEM must be installed in column 1,
sections 1, 5, and 9 on the tower.
1. Calibration targets
2. Using both hands, gently push the magazine
downwards until it snaps into place.
NOTE: Make sure that all four tabs are
full engaged and that the back of the
magazine is flush with the side of the
HDEM tower.
3. Using the above steps, reinstall any magazine(s)
that needed to be removed in order to access the
magazine needing replacement.
4. Replace any media that needed to be removed.
5. Close the front access door.
Prepare the library for use
1. On the operator panel, press the Robotics Enabled
button to enable the picker assembly.
2. Run the Configure and Calibrate teach test. See
HP StoreEver Enterprise Systems Library (ESL) G3
Tape Library User Guide, Teaching the Library
(Configuration and Calibration) section.