Use a multimeter
if available to
measure the
resistance shown
on the PCI back
plane. If the
multimeter shows
a short, check the
expansion cage
and fan to ensure proper connections, then proceed to
the HP StorageWorks e2400-160 Fibre Channel
interface controller installation instructions.
Install the Fibre Channel interface controllers that were
previously removed into the bottom two slots of the
expansion cage. Align the edges of the controller with
the card guides in the expansion cage. Push the
controller into the cage and pivot the ejector handles
toward each other to fully seat the controller. Using a
Phillips screwdriver, tighten the two captive screws on
the ejector handles.
18
19
Reconnect the SCSI cables that go from the Fibre
Channel interface controllers to the library’s SCSI