LTO 960 SCSI G66D Firmware release notes (Q1538-90930, June 2008)

Description
This document outlines the main changes for the G66D rmware maintenance release version. These
changes are a combination of customer reported issues and enhancements found via HP internal testing.
Update recommendation Recommended
Supersedes G64D
Product models
HP Storageworks 960i Q1538A
HP Storageworks 960e Q1539B
HP Storageworks 960m (Rack Mount) Q1540A
Operating systems
Cross opera
ting system (BIOS, Firmware, Diagnostics, etc.)
Enhancements
In this code release, the Drive Error LED is turned on when a DSP fault 0x7708 (Actuator Stroke Size
Too Small) occurs.
Fixes
Drive hangs
This code introduces improvements for hangs which could occur during writing operation.
Read/space issues
This code
version introduces improvements in the logical positioning function to cater for the rare
occasion
s where non-inquiry fast commands are aborted.
This code revision introduces improvements in reading tapes written by non-HP drives. Those
improvements are an additional read retry and a change to an existing read retry algorithm, as
wellasintheformofmoreoptimizeddrivetuning.
This cod
e version introduces improvements in spacing/positioning o perations for corner case
scripts
which use very large record sizes. In c ases where 1Mb/2Mb records were written and
2Mb/4M
b reads were requested, possible m ispositioning errors are eliminated.
This co
de introduces improvements for hangs which could occur during writing o peration.
Write issues
This code introduces improvements in the DSP tape expansion and tape tilt algorithms, to help in several
situations, such a s when thermal events occur.
Cartridge, cartridge memory and MAM
This code version introduces a feature to avoid any unnecessary warning messages from an LTO-4
compliant software application.
LTO 960 SCSI G66D Firmware release notes
3