HP StorageWorks Ultrium Full-Height SCSI Tape Drives User Guide (EH853-90905, August 2007)

1and7 termin
ated SCSI cable
2and4 powercable
3
tape drive
5
server’s power supply
6
SCSI controller
Figure 8 Connecting p ower and SCSI ca bles
Where should the SCSI terminator be?
Termination must be present at two and ONLY two positions on the SCSI bus—at the beginning of the
SCSI bus and at the end of the SCSI bus. Termination is normally enabled by default on the HBA and
most internal SCSI cables have a terminator attached. This will usually be a small, rectangular block
of plastic attached to the cable end and ma rked ‘SCSI Terminator’.
Therefore, assuming the HBA is the rst device on the bus, you should check that the second terminator is
placed after the last device, as shown in Figure 8, item 1 .
Ultrium full-height SCSI Tape D rives
27