Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 219
53-1000599-02
firmwareShow
2
firmwareShow
Displays the Fabric OS versions on all firmware partitions in the system.
Synopsis firmwareshow
Description Use this command to display the FOS, SAS, and SA firmware versions. The command shows the
firmware versions on both the primary and secondary partitions of the storage device.
Note The execution of this command is subject to Admin Domain restrictions that may be in place.Refer
to chapter 1, “Understanding Admin Domain Restrictions” and Appendix A, “Command Availability”
for details.
Operands none
Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7:
switch:admin> firmwareshow
Slot Name Appl Primary/Secondary Versions Status
-----------------------------------------------------------
2 FA4-16 FOS v6.1.1
v6.1.1
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
5 CP0 FOS v6.1.1 Standby *
v6.1.1
6 CP0 FOS v6.1.1 Active
v6.1.1
7 FA4-16 FOS v6.1.1
v6.1.1
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
* Local CP
Note: If Local CP and Remote CP have different versions, retry the
firmwaredownload command.
To display the firmware version on a switch:
switch:admin> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v6.1.1
v6.1.1
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
See Also firmwareDownload, firmwareDownloadStatus