Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
234 Fabric OS Command Reference
53-1000599-02
fwFruCfg
2
fwFruCfg
Displays or modifies FRU state alert configuration.
Synopsis fwfrucfg [--show]
Description Use this command to configure field-replaceable unit (FRU) states and actions. Based on these
configuration settings, Fabric Watch generates action when a FRU state changes. To configure
email alerts, use fwMailCfg.
Notes This command requires a Fabric Watch license.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
The command is not applicable to platforms without FRUs.
Operands This command has the following operand:
--show Displays the current FRU configuration setting.
If no operand is specified, the configuration prompt displays.
Examples To change FRU state alert configuration:
switch:admin> fwfrucfg
The current FRU configuration:
Alarm State Alarm Action
-----------------------------------------------
Slot 0 1
Power Supply 0 0
Fan 0 0
WWN 0 0
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0] 3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed
See Also fwConfigure, fwMailCfg