Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 245
53-1000599-02
fwSetToCustom
2
1 : Temperature
2 : Fan
3 : Power Supply
4 : return to previous page
Select an area => : (1..4) [4] 1
Index ThresholdName Status CurVal
LastEvent LasteventTime LastVal LastState
================================================================================
1 envTemp001 enabled 24 C
inBetween Thu Feb 14 01:21:36 2008 24 C In_Range
4 envTemp004 enabled 23 C
inBetween Thu Feb 14 01:21:36 2008 23 C In_Range
5 envTemp005 enabled 30 C
inBetween Thu Feb 14 01:21:36 2008 30 C In_Range
6 envTemp006 enabled 32 C
inBetween Thu Feb 14 01:21:36 2008 31 C In_Range
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5] 4
Index ThresholdName BehaviorType BehaviorInt
1 envTemp001 Triggered 1
4 envTemp004 Triggered 1
5 envTemp005 Triggered 1
6 envTemp006 Triggered 1
Threshold boundary level is set at : Custom
Default Custom
Unit C C
Time base
Low 0 0
High 60 60
BufSize 10 10
Threshold alarm level is set at : Custom
Errlog-1, SnmpTrap-2, RapiTrap-8
EmailAlert-16
Valid alarm matrix is 27
Default Custom
Changed 0 0
Below 3 3
Above 3 3
InBetween 3 3
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes