Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
412 Fabric OS Command Reference
53-1000599-02
perfShowPortEEMask
2
perfShowPortEEMask
Displays the current address mask for end-to-end performance monitors on a port.
Synopsis perfshowporteemask [slotnumber/]portnumber
Description Use this command to display the current mask shared across all end-to-end (EE) performance
monitors of a port. There are only two commands that can modify the value of the EE mask:
perfSetPortEEMask and perfCfgRestore.
The end-to-end mask has 12 fields:
TxSID Domain: on
TxSID Area: on
TxSID ALPA: on
TxDID Domain: on
TxDID Area: on
TxDID ALPA: on
RxSID Domain: on
RxSID Area: on
RxSID ALPA: on
RxDID Domain: on
RxDID Area: on
RxDID ALPA: on
The fields that are marked “on” are used to trigger end-to-end monitors. The default value of the EE
mask is all fields set to “on.”
Notes This command requires an Advanced Performance Monitoring license.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and
GbE ports.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command has the following operand:
slotnumber For bladed systems only, this operand specifies the slot number of the port
on which the monitor is to be displayed, followed by a slash (/).
portnumber Specifies the number of the port on which the monitor is to be displayed,
relative to its slot for bladed systems. Use switchShow for a list of valid ports.
Examples To display the end-to-end mask on a port:
switch:admin> perfshowporteemask 2/4
The EE mask onport 20 is set by application NONE
TxSID Domain: on
TxSID Area: on
TxSID ALPA: on
TxDID Domain: on
TxDID Area: on
TxDID ALPA: on
RxSID Domain: on
RxSID Area: on