Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 515
53-1000599-02
portShow
2
Testing Running diagnostics.
Faulty Failed diagnostics.
Persistently Disabled
Persistently disabled.
portPhys The port's physical state:
No_Card No interface card present.
No_Module No module (GBIC or other) present.
No_Light Module is not receiving light.
No_Sync Receiving light but out of sync.
In_Sync Receiving light and in sync.
Laser_Flt Module is signaling a laser fault.
Port_Flt Port marked faulty.
Diag_Flt Port failed diagnostics.
Lock_Ref Locking to the reference signal.
portScn The port’s last State Change Notification.
port generation number
The port’s generation number for the last offline state change.
portId The port’s 24-bit port ID.
portIfId The user port’s interface ID.
portWwn The port’s World Wide Name.
portWwn of devices(s) connected
The World Wide Port Names of connected devices.
Distance The port's long-distance level. In case of LD mode, the user configured
distance and actual distance also are displayed. See portCfgLongDistance for
information on long distance levels.
portSpeed The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2
Gbps, N4Gbps, N8 Gbps or AN).
LE domain The LE domain ID.
FC Fastwrite The status of FC Fastwrite (ON or OFF).
If the port is configured as an EX_Port, the following additional port information is displayed:
EX_Port Mode The port is configured as an EX_Port.
Fabric ID The fabric ID assigned to this EX_Port; therefore, it is the fabric ID of the edge
fabric attached to this EX_Port.
Front Phantom Information on the front phantom domain presented by this EX_Port. Includes
the preferred (if not active) or actual (if active) domain ID for the front domain
and the WWN of the front domain.
Pr Switch Info Information on the principal switch of the edge fabric attached to this
EX_Port. Includes the domain ID and WWN of the principal switch.