HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
IPL file is not getting updated, when a PDCM matrix is activated using
WebTools with Active=Save Mode checked.
Fixed in Fabric OS 6.3.0
Fabric Watch failed to initialize on fully populated HP StorageWorks
DC SAN Backbone Director.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Avoid querying FcFeModuleName
or (connUnitPortFCId in AG
mode) MIB to avoid memory leak.
Memory leak when querying connUnitPortFCId in Access Gateway
(AG) mode and also when querying FcFeModuleName.
Fixed in Fabric OS 6.3.0
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when the FCR routes are being processed, resulting
in missing FCR routes and an inability to route traffic across VEX ports.
Fixed in Fabric OS 6.3.0
CUP Port present CU-Busy on one path and never sending CU-End to
clear busy.
Fixed in Fabric OS 6.3.0
In B2E routed environment, when user executes pathinfo command
in BB querying for xlate domain, the switch may panic.
Fixed in Fabric OS 6.3.0
Observed kernel panic on a DC SAN Backbone Director in RTE module.
Fixed in Fabric OS 6.3.0
Switches leaking memory slowly over extended period while being
managed by DCFM.
Fixed in Fabric OS 6.3.0
Switchdisabling all switches in the fabric causing all HP Storage-
Works 4/256 SAN Director switches Out of Memory: Killed
process 2337 (iswitchd).
Fixed in Fabric OS 6.3.0
License problem observed after configdownload and QoS license
was checked for 4G platforms at CLI.
Fixed in Fabric OS 6.3.0
Unable to configure ports using configdownload.
Fixed in Fabric OS 6.3.0
Portcams and NS zonemembership data are missing for hard-zoned
ports.
Fixed in Fabric OS 6.3.0
Software was not enforcing a mandatory switch disable before config-
uring the backbone Fabric ID.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not use logical switches.
Failover when Logical Switch (LS) trans incomplete Observed and
Panic. Ficud terminated detected when FID is created
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Power off and then Poweri on the
Switch via OA.
ISMIC - When a reset of a HP-VC is done via the OA, the vcfcadm_
user password is NOT generated as seen from the console log, thereby
causing a NO COMM on the VCM.
Fixed in Fabric OS 6.3.0
Workarounds prior to code change:
1. Slotpoweroff and
slotpoweron always recovers the
blades. 2. DC04 SAN Director
reboots also recover the blades.
Swapping HP StorageWorks 32 port 8Gb FC blade with 48 port
blade in DC04 SAN Director initializes both to a Faulty-51 state.
HP StorageWorks Fabric OS 6.3.0d Release Notes 47