HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
In non-VF mode on DC SAN Director, after removing other filters (EE
and F_Port TT) and enabling Fabric mode TopTalkers, the flow values
are not reliable.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Mannually block and unblock an
E_Port to rebuild the fabric.
HA Failover on DC SAN Director caused: Need to reboot the system
for recovery, reason: System bring up timed out.
Fixed in Fabric OS 6.3.0
In Access gateway mode,Port swap and Enable/Disable NPIV option
is enabled in WebTools.
Fixed in Fabric OS 6.3.0
As DCFM polling LUNs, the memory usage for weblinker is increased.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Logout all the devices registered their
HBA info and log them in after the
fabric is stable.
FDMI: fdmid crashes when a brocade HBA with virtual ports is connec-
ted to a 4/256 SAN Director.
Fixed in Fabric OS 6.3.0
Brocade 8000 firmware download hot code load shows no identifier
in the HTML page.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Activate the same PDCM Matrix from
WebTools, with Active=Save Mode
checked from Edit CUP Port
Connectivity Configuration window.
Unable to activate a new PDCM Matrix with WebTools.
Fixed in Fabric OS 6.3.0
VCM dont have GUI capability to change SNMP read community
configuration.
Fixed in Fabric OS 6.3.0
8/80 SAN Switch: Removing any power supply FRU causes fans to
speed up for a short period (which is not expected).
Fixed in Fabric OS 6.3.0
The SFP parameters are not returning for the ports which are under
the logical switches other than the default logical switch.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Specify the slot number for which the
command is directed. For example,
ptsupportshow 1 -all command
to see all ports on blade 1.
ptsupportshow -all does not function properly.
Fixed in Fabric OS 6.3.0
WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04
SAN Director.
Fixed in Fabric OS 6.3.0
Applications cannot distinguish between Multiprotocol Router Blade
and Core blades on DC SAN Director using SNMP. Need to add two
new FRU classes: "coreblade" and "applicationblade" class.
Fixed in Fabric OS 6.3.0
Switch panic in ficon enviormnet when blocking/unblocking E-Port due
to RNID data count is incorrect.
Fixed in Fabric OS 6.3.0
Switch Admin: when user moves to a different tab without applying
changes, no warning is displayed.
HP StorageWorks Fabric OS 6.3.0d Release Notes 59