HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
Encryption SAN Switch panic because KACd memory leak with multiple
get key operation.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Set defzone to "noaccess."
FR zones cannot be created when defzone is set to "allaccess."
Fixed in Fabric OS 6.3.0
The lfcfg command shows incorrect data.
Fixed in Fabric OS 6.3.0
Switch Admin: Policies which are not chosen are showned in confirm-
ation page of ACL Policy configuration wizard.
Fixed in Fabric OS 6.3.0
When attempting to swap ports from the GUI, the operation may fail
due to HTTP 500 error.
Fixed in Fabric OS 6.3.0
Agd aborted due to *** glibc detected *** free(): invalid next size
(fast).
Fixed in Fabric OS 6.3.0
DWDM link unable to sync up before port is enabled at correct speed.
Fixed in Fabric OS 6.3.0
Bad SFP triggered i2c access cause issues on port/slot disaplay and
cpu load on 4/256 SAN Director.
Fixed in Fabric OS 6.3.0
Cryptocfg show transshow when issued without any outstanding
transactions displayed Operation "failed" with an incorrect cause.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Other methods of creating TI Zones
and modifying the definitions work
seamlessly. Its just this odd set of steps
that produce the failing condition.
When creating multiple TI zones, they
should be saved before modifying the
attributes. Can clean up problem by
using zone --add to modify the
attributes again after the save. Can
also delete and re-create TI zone.
Sequence of creating two TI zones, not saving the change and then
modifying the attributes with the "zone --add" command results in
misconfigured attributes that will cause software verify on remote
switches when changes are committed.
Fixed in Fabric OS 6.3.0
Specific call to CEE library results in gradual memory leak.
Fixed in Fabric OS 6.3.0
Getting ms_ficon errors on console of core DC SAN Director in
McDATA interop after reboots.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Use CLI to add the tag names back
onto the FCR switch.
Configdownload fails with Lsan tag download failed: Duplicate tag.
Fixed in Fabric OS 6.3.0
In Interopmode 2 mode, FC address is shown without offset in
switch.html and portshow (cli), but shown with offset in
switchshow.
62