HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
System will recover.
While performing security related fabric wide operations if fabric be-
comes unstable, user might observe verify on standby.
Fixed in Fabric OS 6.3.0
Setting the E-Net portname on the Primary CP does not get copied
over to the standby CP.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not overlap effective and default
zones on the same NPIV port,
following best practices guidelines.
NPIV devices on a single port are spread across effective and McDATA
default configurations, only devices from default configuration can
establish communication.
Fixed in Fabric OS 6.3.0
Access Gateways connected to EOSc in a mixed fabric (Fabric OS
and EOS) are not shown in DCFM.
Fixed in Fabric OS 6.3.0
Not able to add EE monitor on port 1 after firmware upgrade from
6.1.0c to 6.2.0 on 400 Multiprotocol router.
Fixed in Fabric OS 6.3.0
Nsinfo.htm returns NPIV info as Physical if non-VF switch is connected
to VF enabled platform.
Fixed in Fabric OS 6.3.0
CP experienced a kernel panic "Oops: kernel access of bad area, sig:
11 [#1]".
Fixed in Fabric OS 6.3.0
Fruclass in fru table and fruhistoryclass in fruhistorytable of HA MIB
shows other(1) for CP slot instead of cp(4) for DC SAN Director and
DC04 SAN Director.
Fixed in Fabric OS 6.3.0
CPstatus change trap is not generated on issuing HA failover for 4/256
SAN Director, but the failover happens and the CP status change oid
returns changed values.
Fixed in Fabric OS 6.3.0
Workaround prior to code change: A.
DCFM can be used to add the port
fencing policy for F_Port. B. Existing
Fabric OS CLI can always be used to
add port fencing policy after bringing
up F_Port on a switch. Adding port
fencing policy for F_Port makes sense
only when there are F ports on a
switch and anyway the existing CLI
behavior takes care of this.
Fabric OS CLI doesn't allow Port fencing policy addition for F_Port
when there are no F_ports on the switch.
Fixed in Fabric OS 6.3.0
Not getting GbE ports while performing EnumerateAssociatedInstances
on Brocade_LogicalSwitch.
Fixed in Fabric OS 6.3.0
Switch doesn't commit after firmwareDownload fail as 0x23 (time
out).
Fixed in Fabric OS 6.3.0
Appropriate message is not shown in the message box, when the
"Details" button in the "Service" tab of "HA" window is clicked.
Fixed in Fabric OS 6.3.0
High Availability: The error message thrown is not relevant or mean-
ingful, when the values for E_D_TOV and R_D_TOV in the Configure
tab of Switch admin, are changed.
Fixed in Fabric OS 6.3.0
Incorrect output from agshow command.
64