HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not update the configuration when
systemVerification is running. If user
accidentally changes configuration
when the command was executing,
use "burninlevel 0" to recover from
this situation.
Changing configuration using configure or configDownload when
systemVerification is executed could lock out the systemVeri-
fication from being executed subsequently.
Fixed in Fabric OS 6.3.0
Channel definition errors; time out on QSA Response due to excessive
link incidents.
Fixed in Fabric OS 6.3.0
The ifNumber does not match the number of entries in the ifTable for
the logical switches with LISL.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Don't use date command in
non-default logical swtich.
Newly created LS should inherit NTP server setting of Default LS.
Fixed in Fabric OS 6.3.0
Allowed to add a F_Port TT Monitor to mirror port, however no counters
display.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Toggle the physical port.
Virtual nodes on the same switch port may not be able to communicate
due to missing RSCNs and the CAM not be programmed. This is not
a likely scenario.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
When the system is working well,
save that configuration somewhere so
that it can be reapplied instead of
relying on portcfgdefault.
Command portcfgdefault performed on an internal F_Port will
convert that F_Port into an N_Port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Delete and re-install EE Monitors.
EE monitor counter is not incrementing after firmware upgrade to 6.2.0.
Fixed in Fabric OS 6.3.0
ISL monitor total transmit and number of destination domains monitored
counters show 0 when traffic is running thru this ISL.
Fixed in Fabric OS 6.3.0
SNMP: The swNs Table does not list all the name server entries.
Fixed in Fabric OS 6.3.0
Interopmode 2 - Value other than 0 or 1 in configdownload file will
enable default zone; I was expecting an error message.
Fixed in Fabric OS 6.3.0
IP monitor shows number of SCSI frames after deleting a SCSI filter
monitor and adding IP monitor on the same port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Switch name can be displayed from
Fabric OS CLI command -
switchname.
Onboard Administrator used to manage 8 Gb SAN Switch for
BladeSystem c-Class is not able to read the switchname.
Fixed in Fabric OS 6.3.0
Statsclear does not clear porterrshow statistic data for field
"link fail " on 6-port 10Gb/s ISL blade.
HP StorageWorks Fabric OS 6.3.0d Release Notes 69