HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0a
Zoning fails with Transaction Commit failed. Reason code
2 (26) - Aca was rejected: Remote Switch Busy, Retry
in a few seconds error when E_Port to neighboring Mi10k is lost
during a zone push operation when in interop mode.
Fixed in Fabric OS 6.3.0a
I/O traffic with 1606 Extension SAN Switch or Multiprotocol Extension
Blade unable to run across edge-to-edge topology when compression
and FastWrite are enabled in certain Virtual Fabric configurations.
Fixed in Fabric OS 6.3.0a
Workaround prior to code change:
Execute the command again to obtain
the correct values.
SFP power-supply values are not displayed correctly after doing a
nondisruptive firmware upgrade to Fabric OS 6.2.1.
Fixed in Fabric OS 6.3.0a
FCIP tunnel may bounce up and down in an impairment network con-
figuration with compression enabled and highly compressible data
I/O with either the 1606 Extension SAN Switch or Multiprotocol Ex-
tension Blade.
Fixed in Fabric OS 6.3.0a
With either the 1606 Extension SAN Switch or Multiprotocol Extension
Blade, VE tunnel did not come up due to configuration mismatch for
tape pipelining. One side shows Write only and the other side
shows Write/Read.
Fixed in Fabric OS 6.3.0a
High CPU load from DCFM performing supportsave causes port to
go offline with laser FLT/link reset.
Fixed in Fabric OS 6.3.0a
Name server database counts do not match for Fabric OS (6.2.1) and
M-EOS (9.9.0) switches in the same fabric, so host cannot see the
device. This occurs when an HBA capable of a FDMI Register HBA
(RHBA) command and M-EOS switch are in the same fabric.
Fixed in Fabric OS 6.3.0a
Workaround prior to code change:
Configure only DISLs between
switches.
Switch panic triggered by size-64 kernel message buffer being used
up in virtual fabric with logical ISL configured.
Fixed in Fabric OS 6.3.0a
During factory install, configdownload does not download some
of the FCoE settings in Fabric OS 6.3.0. This issue pertains to the
factory only and will not be encountered in the field.
Fixed in Fabric OS 6.3.0a
Port reference provided to FICON host by Director History Buffer incor-
rectly references port address rather than port number. This can cause
the host to reference the wrong port.
Fixed in Fabric OS 6.3.0a
With Fabric OS 6.2, B-series switch in interopmode 3 experiences an
NSD panic with C-series switch in interop mode.
Fixed in Fabric OS 6.3.0a
Workaround prior to code change:
Use slotpoweroff and
slotpoweron to clear the fault.
Transient detected error on internal link caused 8-Gb blade to be
faulted with reason=5.
Fixed in Fabric OS 6.3.0a
After downgrading to 6.2.0x from 6.3.0, when you execute the fw-
configure --eport --ST command runs, the threshold will be
set to 63, which is not allowed in Fabric OS 6.2.
72