HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

SolutionClosed defect summary
Fixed in Fabric OS 6.3.0b
Workaround prior to upgrade:
Use the CLI to view the configured
IOD state when IOD is enabled with
the Lossless DLS solution.
When Lossless DLS is enabled, WebTools incorrectly shows iodset
off, but the CLI shows that it is enabled.
Fixed in Fabric OS 6.3.0b
In a rare case, a buffer leak in the rekey daemon causes an HP Stor-
ageWorks Encryption SAN Switch fault during rekey. A power cycle
is required to recover.
Fixed in Fabric OS 6.3.0b
HP StorageWorks Encryption SAN Switch does not rejoin Encryption
Group after a reboot, resulting in a split Encryption Group.
Fixed in Fabric OS 6.3.0b
Incorrect port shows I/O traffic on 2408 FCoE Switches and 10/24
FCoE Blades.
Fixed in Fabric OS 6.3.0b
When launched from DCFM, WebTools fails with a license error.
Fixed in Fabric OS 6.3.0b
The host cannot recover if a back-end tape target becomes unrespons-
ive during encryption switch-initiated commands.
Fixed in Fabric OS 6.3.0b
With an HP StorageWorks 1606 SAN Extension Switch and an Mul-
tiprotocol Extension Blade, smart data for GE-type ports (such as SFP
temperature and power) are not updated in sfpshow by the automatic
polling loop.
Fixed in Fabric OS 6.3.0b
The supportsave command does not capture information for FIDs
with index >3.
Fixed in Fabric OS 6.3.0b
On an 8 Gb switch in Access Gateway mode connected to another
switch running Fabric OS 6.2.x or earlier, links on the Access Gateway
device enter a disabled state and report NPIV not supported by
Fabric port, even though the edge switch port has NPIV enabled.
Fixed in Fabric OS 6.3.0b
With either the 2408 FCoE Switch or the 10/24 FCoE Blade, when
selecting FCoE Login in the Element Manager under switch admin,
the error message FCoE Login Management is disabled in
the switch, make sure you enabled it to view the
chassis appears.
Fixed in Fabric OS 6.3.0b
On an HP StorageWorks DC SAN Director Switch Multiprotocol Exten-
sion Blade or 1606 Extension Switch, the portdisable xge0 CLI
command does not disable the port, even though the RAS log and
switchshow list it as disabled.
Fixed in Fabric OS 6.3.0b
Workaround prior to upgrade:
Disable FICON XRC Emulation.
FICON emulation mode fails when trying to vary paths online to exten-
ded DASD devices with MVS IOS444I error messages.
Fixed in Fabric OS 6.3.0b
Workaround prior to upgrade:
Rerun firmwaredownload.
In a fabric with more than 50 switches, non-disruptive firmware
downloads (HCL) on an HP StorageWorks DC SAN Director fails on
the standby CP.
74