HP Emulex Adapters Release Notes

On Microsoft Windows 2003 and Microsoft Windows 2008, the link is not re-established when
a Cisco Nexus 5000 switch is rebooted. The workaround is to use the Nexus Shutdown and No
Shutdown CLI commands to bring the port back online.
STORport miniport driver installation restrictions
If you are upgrading to the STORport miniport driver, consider the following:
The STORport miniport driver is supported on Microsoft Windows 2003 SP1 and later.
Microsoft hotfix KB932755 must be installed before installing Multipath software.
When running Secure Path for Windows, upgrade to Secure Path 4.0c SP2 or later for
Windows. STORport is not supported with earlier versions of Secure Path.
WS2003 restriction for Integrity servers
Integrity servers running WS2003 support Windows STORport driver 2.10x1 or earlier.
2-Gb HBA/mezzanine card restriction
Emulex 2-Gb HBAs and mezzanine cards are not supported with WS2008 R2.
Smart Component notes
The following Smart Component issues may be observed during driver installation:
When using the Smart Component to install drivers, if the following message appears during
reboot, ignore it and continue with the reboot procedure. No known issues have been observed
in connection with the display of this message.
The application failed to initialize because the windows station is
shutting down.
Downgrading to STORport driver Version 2.0 or later does not work when initiated via the
Smart Component. To downgrade an HP-branded Emulex HBA:
1. Run the Smart Component containing the desired driver and extract the contents to a
folder.
2. Run the STORport driver installer from the extracted folder using the default values. For
example:
storportminiportcorekit_2-01a4
This removes the current driver before downgrading to the specified driver version.
When using the Smart Component to install drivers, the following message may appear during
reboot:
There was a problem installing this hardware. This device is not
working properly because Windows cannot load the drivers required
for this device. (Code 31)
Uninstall and then reinstall your device.
If the above message appears, click Finish and continue with the reboot procedure. Do not
reply to Microsoft. No known issues have been observed in connection with the display of
this message.
Windows BFS notes
In a direct connect environment, BFS fails after a second path is added to an
EVA4000/6000/8000 running firmware 6.110.
BFS on c-Class blade servers fails on an active/passive MSA1000/1500 running firmware
5.20.
14