Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

234 Fabric OS Command Reference Manual
53-1000436-01
filterTest
2
-txports itemlist Specify the user port numbers to perform this test. All user ports are set by
default.
-scamoff offset Specify the program location to write SCAM test data in SCAM memory. The
default value is 0. The maximum offset number is set if the specified number
is larger than the limit.
-dcamoff offset Specify the program location to write DCAM test data in DCAM memory. The
default value is 0. The maximum offset number is set if the specified number
is larger than the limit.
-fdefoff offset Specify the program location to write filter test definition data in filter
definition memory. The default value is 0. The maximum offset number is set
if the specified number is larger than the limit.
Examples To run a frame filter test:
switch:admin> filtertest -txports 3/1-3/3
Running filtertest ..............
Test Complete: filtertest Pass 1 of 1
Duration 0 hr, 0 min & 2 sec (0:0:2:679).
passed.
Diagnostics When it detects failures, the subtest might report one or more of the following error messages:
DIAG-ACTTEST
DIAG-FLTINIT
DIAG-FLTRCV
DIAG-FLTXMIT
DIAG-NUMTEST
Refer to the Fabric OS Message Reference for more information.
See Also itemList