Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

244 Fabric OS Command Reference Manual
53-1000436-01
firmwareShow
2
firmwareShow
Displays the Fabric OS versions on both partitions of the local and remote CPs.
Synopsis firmwareshow
Description Use this command to display the FOS, SAS and SA versions in a Brocade switch or director. It shows
the firmware versions on both the primary and secondary partitions of the storage device.
Operands none
Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7.
switch:admin> firmwareshow
Slot Name Appl Primary/Secondary Versions Status
-----------------------------------------------------------
2 FA4-16 FOS v5.3.0
v5.3.0
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
5 CP0 FOS v5.3.0 Standby *
v5.3.0
6 CP0 FOS v5.3.0 Active
v5.3.0
7 FA4-16 FOS v5.3.0
v5.3.0
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
* Local CP
Note: If Local CP and Remote CP have different versions, retry the
firmwaredownload command.
To display the firmware version of a Brocade switch:
switch:admin> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v5.3.0
v5.3.0
SAS v3.0.0
v3.0.0
DMM v3.0.0
v3.0.0
See Also firmwareDownload, firmwareDownloadStatus