Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 677
53-1000436-01
switchShow
2
Proto Protocol support by GbE port.
ISCSI Ports support ISCSI.
FCIP Ports support FCIP.
comment The comment field is blank, or displays:
Disabled Port is disabled.
Bypassed Port is bypassed (loop only).
Loopback Port is in loopback mode.
E_Port Fabric port; displays WWN and name of attached switch. If the port is
configured as EX_Port, the WWN of the attached switch is the same as the
router.
F_Port Point-to-point port; displays WWN of attached N_Port.
G_Port Point-to-point but not yet E_Port or F_Port.
L_Port Loop port; displays number of NL_Ports.
EX_Port Router port; displays WWN of the attached edge switch.
Mirror Port The port is a mirror port.
(Trunk master) Port is the master port in a group of trunking ports.
(Trunk port, master is port #x)
Port is configured as a trunking port; the master port is port #x.
(upstream) E_Port is an upstream path toward the principal switch of the fabric.
(downstream) E_Port is a downstream path away from the principal switch of the fabric.
Persistently Disabled
This port has been disabled using portCfgPersistentDisable.
FICON Persistent DID
This port has been disabled since the switch could not obtain its
configuration domain ID during the fabric reconfiguration when ficonMode
was enabled. See ficonMode help page for more information.
Fabric ID conflict Two different fabrics have been assigned the same fabric ID ( EX_Ports only).
Fabric ID oversubscribed
One fabric has been assigned two different fabric IDs (EX_Ports only).
If a port is configured as a long distance port, the long distance level is displayed in the format of
Lx, where x represents the long distance level number. See portCfgLongDistance for the level
description.
The port state for disabled E_Ports display as In_Sync when the port is the interswitch link (ISL)
between a Brocade 48000 and a Brocade 24000. If the ISL is between a Brocade 48000 and a
Brocade 4100 or 200E, the disabled E_Port displays as No_Sync.
NOTE
On a Brocade 7600 switch, if the SAS image is not consistent with the FOS image, "(SAS
Virtualization Disabled)" will appear at the end of the output.