Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

5-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
BM-1003
5
BM-1003
Message
Probable
Cause
The CP could not establish a connection to the BP to communicate.
Recommended
Action
Reseat the blade. If the problem persists, power-cycle the blade using the slotPowerOff and
slotPowerOn commands.
Severity WAR NIN G
BM-1004
Message
Probable
Cause
The policy of the specified blade is to auto-level the blade firmware to the system firmware, however
either:
Blade firmware was detected to be different from CP firmware due to a firmware upgrade
The blade was just inserted and had a different firmware version loaded
Recommended
Action
No action is required, the blade will automatically download the updated firmware.
Severity INFO
BM-1005
Message
Probable
Cause
FirmwareDownload of the blade failed.
Recommended
Action
Reseat the blade. If the problem persists, power-cycle the blade using the slotPowerOff and
slotPowerOn commands.
<timestamp>, [BM-1003], <sequence-number>,, WARNING, <system-name>,
Failed to establish connection between CP and blade in slot <Slot
number>. Faulting blade.
<timestamp>, [BM-1004], <sequence-number>,, INFO, <system-name>,
Blade firmware <Blade firmware> on slot < Slot > is not consistent
with system firmware <System firmware>. Auto-leveling blade
firmware to match system firmware.
<timestamp>, [BM-1005], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for blade in slot < Slot >. Faulting
blade.