Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

9-4 Fabric OS Message Reference
Publication Number: 53-1000242-01
EM-1008
9
For the SilkWorm 200E, 3016, 3250, 3850, 4100, and 4900 replace the switch.
Severity CRITICAL
EM-1008
Message
Probable
Cause
Indicates that a blade inserted in the specified slot is not compatible with the switch chassisConfig
option. The blade is faulted.
Recommended
Action
Replace the blade. Make sure the replacement blade is compatible with your CP type and chassisConfig
setting.
Severity CRITICAL
EM-1009
Message
Probable
Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from
the specified FRU. This might indicate a hardware malfunction in the FRU.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU. Refer to the SilkWorm 48000
Hardware Reference Manual for more information about chassisConfig modes and supported blades.
Severity CRITICAL
EM-1010
Message
Probable
Cause
Indicates that the environmental monitor received an unexpected power-down notification from the
specified FRU. However, the specified FRU still appears to be powered up after four seconds.
Recommended
Action
Try reseating the blade. If this fails to correct the error, replace the blade.
<timestamp>, [EM-1008], <sequence-number>, FFDC, CRITICAL, <system-
name>, Unit in <FRU Id> faulted, incompatible with chassis option
<chassis configuration option>
<timestamp>, [EM-1009], <sequence-number>, FFDC, CRITICAL, <system-
name>, <FRU Id> powered down unexpectedly
<timestamp>, [EM-1010], <sequence-number>, FFDC, CRITICAL, <system-
name>, Received unexpected power down for <FRU Id> But <FRU Id>
still has power