Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

9-6 Fabric OS Message Reference
Publication Number: 53-1000242-01
EM-1014
9
Recommended
Action
If the fruInfoSet command was being run, try the command again; otherwise, the update is
automatically reattempted. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity ERROR
EM-1014
Message
Probable
Cause
Indicates that the environmental monitor was unable to access the sensors on the specified FRU.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity ERROR
EM-1015
Message
Probable
Cause
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
A reboot or power cycle is required to clear the situation.
Severity WAR NIN G
EM-1016
Message
Probable
Cause
Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch.
<timestamp>, [EM-1014], <sequence-number>,, ERROR, <system-name>,
Unable to read sensor on <FRU Id> (<Return code>)
<timestamp>, [EM-1015], <sequence-number>,, WARNING, <system-name>,
Warm recovery failed (<Return code>)
<timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>,
Cold recovery failed (<Return code>)