EM-1035
9
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the FRU.
Severity ERROR
EM-1035
Message
Probable
Cause
Suggests that since both Power Supplies associated with one of the 2 main circuits are present but
faulty, maybe the circuit's switch has been turned off, or the AC power source has been interrupted for
that circuit.
The Switch side value is either "left" or "right" designating which circuit switch, facing the cable side of
the chassis. The Switch side value indicates:
"left": controls the odd numbered power supply units.
"right": controls the even numbered power supply units.
Recommended
Action
Check that the identified AC circuit switch is turned on, that the power cord is properly attached and
undamaged, and that the power source is operating properly.
Severity ERROR
EM-1036
Message
Probable
Cause
Indicates that the specified FRU does not seem to be present on the switch.
If the FRU is a WWN card, then default WWN and IP addresses are used for the switch.
Recommended
Action
Reseat the FRU card.
If the message persists, reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the FRU.
Severity WAR NIN G
<timestamp>, [EM-1035], <sequence-number>,, ERROR, <system-name>, 2
circuit paired Power Supplies are faulty, please check the <Switch
side> AC main switch/circuit to see if it has power.
<timestamp>, [EM-1036], <sequence-number>,, WARNING, <system-name>,
<FRU Id> is not accessible.