Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 12-1
Publication Number: 53-1000242-01
Chapter
12
FABS System Messages
FABS-1001
Message
Probable
Cause
Indicates that the system is low on memory and cannot allocate more memory for new operations. This
is usually an internal Fabric OS problem or file corruption. Description of memory need indicates how
much memory was being requested. The value could be any whole number.
Recommended
Action
Reboot or power cycle the switch.
Severity CRITICAL
FABS-1002
Message
Probable
Cause
Indicates that an internal problem has been detected by the software. This is usually an internal Fabric
OS problem or file corruption.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, run the firmwareDownload command to update the firmware.
Severity WAR NIN G
FABS-1004
Message
<timestamp>, [FABS-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, <Function name> <Description of memory need>
<timestamp>, [FABS-1002], <sequence-number>,, WARNING, <system-
name>, <Function name> <Description of problem>
<timestamp>, [FABS-1004], <sequence-number>,, WARNING, <system-
name>, <Function name and description of problem> process <Process
ID number> (<Current command name>) <Pending signal number>