Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-6 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1018
18
FCR-1018
Message
Probable
Cause
Indicates that the number of proxy devices is greater than allowed by the port resource.
Recommended
Action
Remove excess LSAN zones or devices until the number of proxy devices exported is within the range
allowed by the port resource. Use the fcrResourceShow command to view resources including LSAN
zone resources, LSAN device resources, and proxy device port resources.
Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with
the port resource problem.
LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove,
zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed by zoning
operations or by bringing physical devices offline. For example, disabling the port that a device is
attached to, and then disconnecting the cable or disabling the device.
Severity ERROR
FCR-1019
Message
Probable
Cause
Indicates that the number of EX or VEX port entries being created is greater than allowed by the port
resource.
Recommended
Action
Disable EX or VEX ports until the number of ports is within the range allowed by the port resource. The
EX or VEX port limit is displayed using the fcrRouteShow command. Use the portDisable command
to disable EX ports.
Severity ERROR
FCR-1020
Message
Probable
Cause
Indicates that the number of LSAN zones created within a MetaSAN is greater than the local LSAN
zone database limitations.
<timestamp>, [FCR-1018], <sequence-number>,, ERROR, <system-name>,
FC router proxy device entries exhausted on port <port number>.
<timestamp>, [FCR-1019], <sequence-number>,, ERROR, <system-name>,
EX or VEX port entries exhausted at port <port number>.
<timestamp>, [FCR-1020], <sequence-number>,, WARNING, <system-
name>, Local LSAN zone entries for FC router exhausted; max limit:
<LSAN zone limit>.