Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-10 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1029
18
FCR-1029
Message
Probable
Cause
Indicates that the Port WWN pool has rolled over and WWN entries detected to not be in use are reused
as needed.
Recommended
Action
It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in
a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly
dynamic changes to EX port connectivity. WWN conflicts might cause unpredictable behavior in
management applications.
To avoid WWN conflicts, all EX ports attached to fabrics with highly dynamic changes to EX port
connectivity should be disabled then reenabled.
Severity INFO
FCR-1030
Message
Probable
Cause
Indicates that the physical device WWN came online in the specified fabric.
Recommended
Action
No action is required.
Severity INFO
FCR-1031
Message
Probable
Cause
Indicates that the physical device WWN went offline in the specified fabric.
Recommended
Action
No action is required.
Severity INFO
<timestamp>, [FCR-1029], <sequence-number>,, INFO, <system-name>,
Port WWN pool 95 percent allocated.
<timestamp>, [FCR-1030], <sequence-number>,, INFO, <system-name>,
Physical device <device WWN> came online at fabric <fabric ID>.
<timestamp>, [FCR-1031], <sequence-number>,, INFO, <system-name>,
Physical device <device WWN> went offline in fabric <fabric ID>.