Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-16 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1054
18
FCR-1054
Message
Probable
Cause
Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the other
end of the link.
Recommended
Action
Check the error message log on the other switch using the errShow command for additional messages.
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary.
Run the portLogDumpPort command on both the receiving and transmitting port.
Run the fabStateShow command on transmitting switch.
If the message persists, collect switch information using the supportShow command, and contact your
switch service provider.
Severity WAR NIN G
FCR-1055
Message
Probable
Cause
Indicates that a switch that does not support backbone to edge routing was detected in the backbone.
Edge to edge routing will work, but backbone to edge routing might fail.
Recommended
Action
No action is required if backbone to edge routing is not required. Otherwise replace the switch with one
that supports backbone to edge routing.
Severity INFO
FCR-1056
Message
Probable
Cause
Indicates that a switch that does not support backbone to edge routing is running in the MetaSAN.
<timestamp>, [FCR-1054], <sequence-number>,, WARNING, <system-
name>, Port <port number> received ILS <command> of incorrect size
(<actual payload size>); valid ILS size is <expected payload size>.
<timestamp>, [FCR-1055], <sequence-number>,, INFO, <system-name>,
Switch with domain ID <domain ID> does not support backbone to edge
imports.
<timestamp>, [FCR-1056], <sequence-number>,, INFO, <system-name>,
Switch <switch WWN> with front domain ID <domain ID> does not
support backbone to edge imports.