Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-22 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1071
18
FCR-1071
Message
Probable
Cause
Indicates that the port became an EX or VEX port.
Recommended
Action
No action is required.
Severity INFO
FCR-1072
Message
Probable
Cause
Indicates that the port is no longer an EX or VEX port.
Recommended
Action
No action is required.
Severity INFO
FCR-1073
Message
Probable
Cause
Indicates that a switch in the backbone/edge that supports different limit of LSAN Zones was detected.
Recommended
Action
Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest
supported LSAN zone limits. Please make sure that total number of LSAN zones in the Meta-SAN are
within the lowest supported limit of LSAN zone
Severity INFO
<timestamp>, [FCR-1071], <sequence-number>,, INFO, <system-name>,
Port <port number> is changed from non FCR port to FCR port.
<timestamp>, [FCR-1072], <sequence-number>,, INFO, <system-name>,
Port <port number> is changed from FCR port to non FCR port.
<timestamp>, [FCR-1073], <sequence-number>,, INFO, <system-name>,
Switch with domain ID <domain ID> in fabric <fabric ID> has lower
limit of LSAN Zones supported