Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 19-1
Publication Number: 53-1000242-01
Chapter
19
FICU System Messages
FICU-1001
Message
Probable
Cause
Indicates that one of the configuration management functions failed. The key variable is part of the
Fabric OS configuration database and is for support use only. The error variable is an internal error
number.
Recommended
Action
Execute an haFailover on the switch if it has redundant CPs or reboot the switch. Run the saveCore
command to check if your flash is full. If the flash is full, run the saveCore command to clear the core
files. Refer to the Fabric OS Command Reference for more information on these commands.
Severity ERROR
FICU-1002
Message
Probable
Cause
Indicates that the FICON-CUP daemon failed to get switch RNID from the management server due to a
Fabric OS problem. The domain variable displays the domain ID of the target switch for this RNID. The
error variable is an internal error number.
Recommended
Action
If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a
nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to
the Fabric OS Command Reference for more information on this command.
Severity ERROR
<timestamp>, [FICU-1001], <sequence-number>,, ERROR, <system-name>,
<function name>: config<config Set(key)|Get(key)| Save> failed rc =
<error>
<timestamp>, [FICU-1002], <sequence-number>,, ERROR, <system-name>,
Failed to get RNID from Management Server Domain=<domain>
rc=<error>