Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

25-6 Fabric OS Message Reference
Publication Number: 53-1000242-01
FW-1035
25
Severity WAR NIN G
FW-1035
Message
Probable
Cause
Indicates that the temperature of the SFP has risen above the high boundary. Frequent fluctuations in
temperature might indicate a deteriorating SFP.
Recommended
Action
Replace the SFP.
Severity WAR NIN G
FW-1036
Message
Probable
Cause
Indicates that the temperature of the SFP has changed from a value outside of the acceptable range to a
value within the acceptable range. Frequent fluctuations in temperature might indicate a deteriorating
SFP.
Recommended
Action
No action is required.
Severity INFO
FW-1037
Message
Probable
Cause
Indicates that the receive power value of the SFP has changed. The receive performance area measures
the amount of incoming laser to help you determine if the SFP is in good working condition or not. If
the counter often exceeds the threshold, the SFP is deteriorating.
<timestamp>, [FW-1035], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1036], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1037], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.